NetBackup™ 5240 Storage Shelf Product Description ... NetBackup 5240 Appliance front panel disk drive configuration . ..... After you replace the failed disk drive, the appliance then copies the information from the disk drive in slot 11 to the new replacement disk. .... PROCHOT (Therm Ctrl) sensors. □. VRD Hot asserted. □. Avago Technologies MegaRAID Firmware Release ... SCGCQ01077659 - (Closed) - Jbod showing up in Single drive R0 mode in 240 VD ... ECC Error spike observed during Cache Restore when read eye training failed. ... (Closed) - Handling Direct Attached Storage while updating Topology array ... safeStor - OPAL drive slot info either not shown properly or always shown as ... Intel(R) Server Board S2600WT Technical Product ... - Hammer Intel Dec 3, 2015 ... 7.3.17 Component Fault LED Control . ..... 10.1.3 Peripheral Drive Power Connector . ..... Intel® Server Board S2600WT Memory Slot Layout . ...... Intel® Rapid Storage RAID Technology (RSTe) 4.1 ...... All BMC-owned sensors that show an asserted event status generate a de-assertion SEL event when the.
Drive 3 drive slot sensor drive fault detected - Dell Community
The Storage Monitoring features in Oracle ILOM enable you to view and monitor the ..... The /SYS/INTSW sensor is asserted when the server's top cover is removed while power is ..... Drive Slot : DBP/HDD0/STATE : Drive Fault : Deasserted. ILOM - Oracle Help Center Sep 1, 2012 ... Power Supply Fault Sensors 23. Fan Speed and Physical .... The SNMP Plugins use the Oracle Hardware Storage Access Libraries ... Assistant application from either a local drive attached to the server (CD/DVD or ..... replaced and the updated status is reported as deasserted. .... PCIe slot n, or cluster card. ILOM - Oracle Help Center
I have a Poweredge 6650 that has been running fine with three 72GB drives in a RAID-1 stripe set. It is only powered on when needed as it hosts several VM machi Drive 4 drive slot sensor drive fault detected?
Symptom: HDD Fault Critical SEL events logged in CIMC. description: "HDD1_STATUS: Drive Slot sensor, Drive Fault was asserted" description: "HDD1_STATUS: Drive Slot sensor, Drive Fault was deasserted" Conditions: 1. During RAID rebuild 2. Host Reboot Slot sensor drive fault detected. What does it mean? Mean drive is offline, does not means the HDD is damaged but is no longer detected, however could be related to a physical component. Try run diagnostics, make sure it pass and just rebuild it if it fails or does not rebuild properly contact Dell to avoid data lost.
It was a faulty drive, check the physical box for failure lights, replace, wait for rebuild, should be good.
From OpenManage: Which Controller/backplane component is "Degraded"? ( System - Storage - controller name); Checks logs in System ... IPMI Management Utilities / Support Requests / #21 Drive info and ...
IPMI PET to Platform Message Registry Mapping - DMTF
Error event IDs and error codes: Storwize V7000 6.4.1 - IBM The drive initialization failed because of an unknown block size or a block size that is not valid; an unknown capacity or a capacity that is not valid; or was not able to set the required mode pages. Disk or disk bay Assertion: In Critical Array - Lenovo May 06, 2017 · 05/06/2017 05:43:55 Disk or disk bay 2 (Drive Slot (Bay) - Drive 2): Deassertion: In Critical Array. By what I notice, the drive 2 failed, then drive in slot 3 start to rebuild in order to get into the array, and after completing rebuild., drive 2 went online again, maybe because the lack of stress allow it to , how ever, drive 2 was the one HPE Support document - HPE Support Center Rotation is the part of the robotics assembly that turns the robot to face each magazine and the drive. Sled is the part of the robotics assembly that moves the robot towards the OCP or back towards the drive.
Physical presence sensor—Determines whether the disk drive is inserted in the server drive bay. Physical fault sensor—Determines the operability status reported by the LSI storage controller firmware for the disk drive. IPMI disk drive fault and presence sensors—Sends the sensor results to Cisco UCS Manager. Cisco UCS Integrated Management Controller CLI ... Cisco UCS Integrated Management Controller CLI Configuration Guide for S3260 Storage Servers, Release 4.0-Viewing Faults and Logs ... Server # scope fault Server /fault # show fault-entries Time ... [System Boot] Critical " HDD_01_STATUS: Drive Slot sensor, Drive Presence was deasserted" [System Boot] Informational " DDR3_P2_D1 _INFO: Memory ... Integrated Management Module 2.1 (IMM2.1) error messages ... device is the specific device in the server that caused the event to be generated.. Serviceable Specifies whether user action is required to correct the problem. CIM Information Provides the prefix of the message ID and the sequence number that is used by the CIM message registry. Critical Storage Alert on one of my hosts |VMware Communities That's why you have a drive 7, that's the number matching it's physical slot. If you look at the front of the machine careful, I bet you will see the drive designations, 0,1,2 etc.. That's when you get an error, it will say Drive 3 bad, you know exactly which one to pull or replace.